Home › Products › Transformers › Toroidal transformers › MTS/900 Family
Toroidal transformers
MTS/900 Family
- Toroidal transformers built according to
CE standards CEI 96.1 or CEI 96.2
(IEC 61558-1 / 2-2 / 2–6 / 2-4)
- Single voltage input/output
- Class B insulating materials
- Ambient temperature max. 35 °C
- Extra-low loss grain oriented in core
- Easy to fit and various solutions according
to transformer’s dimensions
- High performance and reduced
dimensions
| Reference Number |
Rated
Output
(VA) |
Dimensions |
Weight
(Kg) |
Fig. |

Various toroidals |
| L |
H |
| MTS/901 |
20 |
70 |
28 |
0,49 |
1 |
| MTS/902 |
30 |
75 |
28 |
0,52 |
1 |
| MTS/903 |
50 |
82 |
32 |
0,61 |
1 |
| MTS/904 |
80 |
92 |
40 |
0,96 |
1 |
| MTS/905 |
100 |
100 |
34 |
1,10 |
1 |
| MTS/906 |
120 |
104 |
37 |
1,28 |
1 |
| MTS/907 |
150 |
115 |
40 |
1,60 |
1 |
| MTS/908 |
200 |
118 |
52 |
2,30 |
1 |
| MTS/909 |
250 |
124 |
54 |
2,60 |
1 |
| MTS/910 |
300 |
135 |
57 |
3,00 |
1-2 |
| MTS/911 |
400 |
145 |
58 |
3,80 |
1-2 |
| MTS/912 |
500 |
155 |
58 |
4,70 |
2 |
| MTS/913 |
700 |
170 |
58 |
5,60 |
2 |
| MTS/914 |
1000 |
180 |
67 |
7,80 |
2 |
| MTS/915 |
1500 |
200 |
72 |
10,0 |
2 |
| MTS/916 |
2000 |
220 |
72 |
12,8 |
2 |
| MTS/917 |
2500 |
230 |
75 |
14,0 |
2 |
| MTS/918 |
3000 |
245 |
87 |
15,6 |
2 |
| MTS/919 |
4000 |
275 |
87 |
19,2 |
2 |
| MTS/920 |
5000 |
320 |
95 |
23,0 |
2 |
 |
It is possible to request customized assemblies, i.e. voltage, number of outputs,
dimensions and output positioning.
The standard outputs present free wires, either with flex cables or rigid wires, depending
on the rated output current, but output wires cabled on various types of
connectors can be supplied.
Between the input and output, a continual copper strip, with yellow/green cable
going out externally, can be connected.
The identification plate states the transformer’s general data, along with the color
of the wires for the input and output of the secondary /secondaries.
The MTA 2000/ 3000 toroidal family is used together with the ASG 2000 / 3000
(see linear stabilized converters), when a 230 or 400V input is needed.
They are assembled with the ASG converters on a rail support and placed vertically
near the converter to save space in width; this safety assembly is possible,
thanks to the reduced dimensions of the toroid.
The output is directly connected to the converter’s input and the input is on a
printed circuit terminal block.
A triple mylar coating between the input and output ensures double isolation
between the windings.
Download PDF format of this tecnichal sheets |