Home › Products › Transformers ›
Single.phase for C.S. › CSG
Family
Single-phase for C.S.
CSG/3000 and CSG/4000 Family
- Toroidal transformers built according to CE
standards CEI 96.1 or CEI 96.2 (IEC 61558-1 / 2-2 / 2–6 / 2-4)
- Primary and secondary single voltage
- Class F insulating materials
- Ambient temperature 35 °C max
- Extra-low loss grain oriented in core
- Extra-low flow loss
- Easy mounting, different systems for each
transformer size
- High performance and reduced dimensions
(half the weight of traditional transformers)
Rated
(A) |
Primary
(V) |
Secon. 2x6
(0/6 0/12) |
Secon. 2x9
(0/9 0/18) |
Secon. 2x12
(0/12 0/24) |
Secon. 2x15
(0/15 0/30) |
| 1 |
230 |
CSG/3001 |
CSG/3101 |
CSG/3201 |
CSG/3301 |
| 2 |
230 |
CSG/3002 |
CSG/3102 |
CSG/3202 |
CSG/3302 |
| 3 |
230 |
CSG/3003 |
CSG/3103 |
CSG/3203 |
CSG/3303 |
| 4 |
230 |
CSG/3004 |
CSG/3104 |
CSG/3204 |
CSG/3304 |
| 5 |
230 |
CSG/3005 |
CSG/3105 |
CSG/3205 |
CSG/3305 |
| 6 |
230 |
CSG/3006 |
CSG/3106 |
CSG/3206 |
CSG/3306 |
| 8 |
230 |
CSG/3007 |
CSG/3107 |
CSG/3207 |
CSG/3307 |
| 10 |
230 |
CSG/3008 |
CSG/3108 |
CSG/3208 |
CSG/3308 |
| 15 |
230 |
CSG/3009 |
CSG/3109 |
CSG/3209 |
CSG/3309 |
| 20 |
230 |
CSG/3010 |
CSG/3110 |
CSG/3210 |
CSG/3310 |
| 25 |
230 |
CSG/3011 |
CSG/3111 |
CSG/3211 |
CSG/3311 |
| 1 |
0/115 0/115 |
CSG/4001 |
CSG/4101 |
CSG/4201 |
CSG/4301 |
| 2 |
0/115 0/115 |
CSG/4002 |
CSG/4102 |
CSG/4202 |
CSG/4302 |
| 4 |
0/115 0/115 |
CSG/4003 |
CSG/4103 |
CSG/4203 |
CSG/4303 |
| 4 |
0/115 0/115 |
CSG/4004 |
CSG/4104 |
CSG/4204 |
CSG/4304 |
| 5 |
0/115 0/115 |
CSG/4005 |
CSG/4105 |
CSG/4205 |
CSG/4305 |
| 6 |
0/115 0/115 |
CSG/4006 |
CSG/4106 |
CSG/4206 |
CSG/4306 |
| 8 |
0/115 0/115 |
CSG/4007 |
CSG/4107 |
CSG/4207 |
CSG/4307 |
| 10 |
0/115 0/115 |
CSG/4008 |
CSG/4108 |
CSG/4208 |
CSG/4308 |
| 15 |
0/115 0/115 |
CSG/4009 |
CSG/4109 |
CSG/4209 |
CSG/4309 |
| 20 |
0/115 0/115 |
CSG/4010 |
CSG/4110 |
CSG/4210 |
CSG/4310 |
| 25 |
0/115 0/115 |
CSG/4011 |
CSG/4111 |
CSG/4211 |
CSG/4311 |
Rated
Output
(VA) |
Sheet |
Dim. (mm) |
Rheofore distance
& No. |
Fig. |
| Column |
Deck |
L |
P |
H |
X1 mm |
X2 mm |
No. |
| 1 |
10 |
10 |
33 |
27 |
25 |
20 |
5 |
5 + 5 |
A |
| 2 |
10 |
15 |
33 |
27 |
30 |
20 |
5 |
5 + 5 |
A |
| 3 |
13 |
13 |
40 |
34 |
29 |
25 |
5 |
5 + 5 |
B |
| 4 |
13 |
15 |
40 |
34 |
31 |
25 |
5 |
5 + 5 |
B |
| 5 |
13 |
20 |
40 |
34 |
36 |
25 |
5 |
5 + 5 |
B |
| 6 |
16 |
16 |
48 |
40 |
35 |
27,5 |
5 |
6 + 6 |
C |
| 8 |
16 |
20 |
48 |
40 |
39 |
27,5 |
5 |
6 + 6 |
C |
| 10 |
16 |
25 |
48 |
40 |
44 |
27,5 |
5 |
6 + 6 |
C |
| 15 |
20 |
20 |
60 |
50 |
44 |
33 |
5 |
7 + 7 |
D |
| 20 |
20 |
25 |
60 |
50 |
49 |
33 |
5 |
7 + 7 |
D |
| 25 |
22 |
30 |
60 |
50 |
54 |
33 |
5 |
7 + 7 |
D |

 |
The transformers of the CSG/3000
and CSG/4000 Family are built according to
the CE standards CEI 96.1 e/o CEI 96.2 (IEC 61558-1, IEC 61558-2-2, IEC 61558-2-6).
They are mainly used for electronic card assembly
and are all built with middle flange coils and
sheaths to assure a perfect insulation between the
primary and secondary. All transformers are
Class F varnish dipped and oven dried.
If connected in series or parallel, the split secondary
offers three equal power voltages. If used
separately, each secondary offers half power
voltage.
The double primary series offers two voltages 230 V o 115 V,
when the series/parallel connection has been
designed on the circuit, as shown in the figure:
|